SSG-H Series - Specs
One-Touch, Strain Gauge Extensometers
SSG25-50H
Types and main specifications
Part No |
346-56752-13 |
---|---|
Gauge length (mm) |
25 |
Applicable sample dNote2 Maximum (mm) : Rod |
ø10 |
Applicable sample dNote2 Maximum (mm) : Flat plate |
W15 x T10 |
Precision |
Guaranteed precision range |
Guaranteed precision range |
Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C |
Weight (g) |
Approx. 64 |
Operational temp. range |
5 to 40 °C |
Power Requirements |
When using the ESA type amplifier: Single-phase 100 V AC 150 VA |
Note 1: The case where an amplifier with a range switching function is used is shown.
Note 2: Not applicable to thin films, thin plates or fine wires.
SSG50-10H
Types and main specifications
Part No |
346-56752-21 |
---|---|
Gauge length (mm) |
50 |
Applicable sample dNote2 Maximum (mm) : Rod |
ø15 |
Applicable sample dNote2 Maximum (mm) : Flat plate |
W25 x T14 |
Precision |
Guaranteed precision range |
Guaranteed precision range |
Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C |
Weight (g) |
Approx. 70 |
Operational temp. range |
5 to 40 °C |
Power Requirements |
When using the ESA type amplifier: Single-phase 100 V AC 150 VA |
SSG25-100H
Types and main specifications
Part No |
346-56752-14 |
---|---|
Gauge length (mm) |
25 |
Applicable sample dNote2 Maximum (mm) : Rod |
ø10 |
Applicable sample dNote2 Maximum (mm) : Flat plate |
W15 x T10 |
Precision |
Guaranteed precision range |
Guaranteed precision range |
Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C |
Weight (g) |
Approx. 72 |
Operational temp. range |
5 to 40 °C |
Power Requirements |
When using the ESA type amplifier: Single-phase 100 V AC 150 VA |
SSG50-10SH*
Types and main specifications
Part No |
346-56752-26 |
---|---|
Gauge length (mm) |
50 |
Applicable sample dNote2 Maximum (mm) : Rod |
ø15 |
Applicable sample dNote2 Maximum (mm) : Flat plate |
W25 x T14 |
Precision |
JIS K7161 measurement range |
Guaranteed precision range |
Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C |
Weight (g) |
Approx. 70 |
Operational temp. range |
5 to 40 °C |
Power Requirements |
When using the ESA type amplifier: Single-phase 100 V AC 150 VA |
SSG75-6SHAD
Types and main specifications
Part No |
346-56752-30 |
---|---|
Gauge length (mm) |
75, 50 variable type |
Applicable sample dNote2 Maximum (mm) : Rod |
ø15 |
Applicable sample dNote2 Maximum (mm) : Flat plate |
W25 x T14 |
Precision |
JIS K7161 measurement range |
Guaranteed precision range |
Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C |
Weight (g) |
Approx. 105 |
Operational temp. range |
5 to 40 °C |
Power Requirements |
When using the ESA type amplifier: Single-phase 100 V AC 150 VA |